Spondees; NU-6 A Short Interval©

This product is the short interval versions of Spondees and NU-6 Form A© (Lists 1-4). These short-interval versions give the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way to speed up administration time, but this version is not recommended for young children or the elderly.

The Spondees is a speech threshold (speech reception threshold-SRT) recording. The Spondees, also known as CID W-1, are two-syllable words with equal stress on each syllable, which are employed to obtain thresholds for speech. There are two randomizations of 36 spondaic words spoken without a carrier phrase for adults. The median speech reception threshold (SRT) for normal listeners is 20 dB SPL (0dBHL).

The Northwestern University Auditory Test Number Six (NU-6) Form A is a phonetically balanced word recognition test that employs CNC words. The talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total). The administration time for the NU-6 short interval is 7-14 minutes instead of 10-19 minutes for the NU-6 standard interval.

The Spondees; NU-6 Form A, Short Interval Version©  includes a) audio recording and b) printed word lists. This product does not include instructions, normative data, or pictures. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests.

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Spondees, NU-6 A, Short Interval Version© (CD Format); Item 145SI; Price $95.00 + S&H Buy Now Button

Spondees, NU-6 A, Short Interval Version© (USB Format); Item USB145SI; Price $101.00 + S&H Buy Now Button

CONTINUE SHOPPING

NU-6 Form C Short Interval©

The Northwestern University Auditory Test Number Six (NU-6) Form C Short Interval© (Lists 1-4) is a phonetically balanced word recognition test that employs CNC words. The male talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total). This NU-6 Form C product includes all of the same 200 NU-6 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is yet another way to effectively speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-14 minutes instead of 10-19 minutes for the standard interval.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

The NU-6 Form C Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

NU-6, Form C Lists 1-4 Short Interval© (CD Format); Item 109SI; Price $59.50 USD + S&H
Buy Now Button

NU-6, Form C Lists 1-4 Short Interval© (USB Format); Item USB109SI; Price $65.50 USD + S&H
Buy Now Button

CONTINUE SHOPPING

NU-6 Form B Short Interval©

The Northwestern University Auditory Test Number Six (NU-6) Form B Short Interval© (Lists 1-4) is a phonetically balanced word recognition test that employs CNC words. The male talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total). This NU-6 Form B product includes all of the same 200 NU-6 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-14 minutes instead of 10-19 minutes for the standard interval.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

The NU-6 Form B Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

NU-6, Form B Lists 1-4 Short Interval© (CD Format); Item 108SI; Price $59.50 USD + S&H Buy Now Button

NU-6, Form B Lists 1-4 Short Interval© (USB Format); Item USB108SI; Price $65.50 USD + S&H Buy Now Button

CONTINUE SHOPPING

NU-6, Form A, Short Interval©

The Northwestern University Auditory Test Number Six (NU-6) Form A Short Interval© (Lists 1-4) is a phonetically balanced word recognition test that employs CNC words. The male talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total).

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-14 minutes instead of 10-19 minutes for the standard interval.

The NU-6 Form A Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

NU-6, Form A Lists 1-4 Short Interval© (CD Format); Item 107SI; Price $59.50 USD + S&H
Buy Now Button

NU-6, Form A Lists 1-4 Short Interval© (USB Format); Item USB107SI; Price $65.50 USD + S&H
Buy Now Button

CONTINUE SHOPPING

W-22 Form A Short Interval©

The W-22 Form A Short Interval© is a phonetically balanced test for word recognition (i.e. speech discrimination). They are made up of consonant-nucleus (CN), nucleus-consonant (NC) and consonant-nucleus-consonant (CNC) words. The talker has a General American dialect. The articulation function is approximately 4% /dB. This product includes all four lists of 50 words each (200 words total).

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-13 minutes instead of 10-18 minutes for the standard interval.

The W-22 Form A Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

W-22, Form A Short Interval© (CD Format); Item 103SI; Price $59.50 USD + S&HBuy Now Button

W-22, Form A Short Interval© (USB Format); Item USB103SI; Price $65.50 USD + S&HBuy Now Button

CONTINUE SHOPPING

W-22 Form D Short Interval©

The W-22 Form D Short Interval© is a phonetically balanced test for word recognition (i.e. speech discrimination). They are made up of consonant-nucleus (CN), nucleus-consonant (NC) and consonant-nucleus-consonant (CNC) words. The talker has a General American dialect. The articulation function is approximately 4% /dB. This W-22 Form D product includes all of the same 200 W-22 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-13 minutes instead of 10-18 minutes for the standard interval.

The W-22 Form D Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

W-22, Form D Short Interval© (CD Format); Item 106SI; Price $59.50 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings and materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

W-22 Form B Short Interval©

The W-22 Form B Short Interval© is a phonetically balanced test for word recognition (i.e. speech discrimination). They are made up of consonant-nucleus (CN), nucleus-consonant (NC) and consonant-nucleus-consonant (CNC) words. The talker has a General American dialect. The articulation function is approximately 4% /dB. This W-22 Form B product includes all of the same 200 W-22 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-13 minutes instead of 10-18 minutes for the standard interval.

The W-22 Form B Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

W-22, Form B Short Interval© (CD Format); Item 104SI; Price $59.50 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings and materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

Spondees; NU-6 Ordered by Difficulty II©

This product consists of a recording of Spondees with a recording of the NU-6 Ordered by Difficulty Version II.

The Spondees is a speech threshold (speech reception threshold-SRT) recording. The Spondees, also known as CID W-1, are two-syllable words with equal stress on each syllable, which are employed to obtain thresholds for speech. There are two randomizations of 36 spondaic words spoken without a carrier phrase for adults. The median speech reception threshold (SRT) for normal listeners is 20 dB SPL (0dBHL). Administration of the Spondees will take approximately seven minutes.

The NU-6 Ordered by Difficulty Version II allows the audiologist to reduce the time of testing in cases where the patient has essentially normal word recognition ability.  It is the result of recent research on our original recording by Raymond Hurley and Janet Sells. This is a recording of a male talker. The lists are ordered from the most difficult to the easiest.  With normal listeners the test can often be terminated after the first 10 words.  This is not a half list; however, there is a provision for termination of the test after 25 words in addition to after the first 10 words.

The Spondees; NU-6 Ordered by Difficulty Version II© includes a) audio recording and b) printed word lists. This product does not include instructions, normative data, or pictures. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US locations.

Spondees, NU-6 Ordered by Difficulty Version II© (CD Format); Item 279; Price $106.00 USD+ S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges.

CONTINUE SHOPPING

PBK A Short Interval©

PBK-50 Form A Short Interval© tests word recognition ability of lower grade school age children. The articulation function is approximately 4%/dB. There are three lists of 50 words (150 words total) available in four different randomizations.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. Administration time is 7-11 minutes.

The PBK Form A Short Interval© includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests.

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

PBK-50, Form A Short Interval© (CD Format); Item 111SI; Price $59.50 USD + S&H
Buy Now Button

PBK-50, Form A Short Interval© (USB Format); Item USB111SI; Price $65.50 USD + S&H
Buy Now Button

CONTINUE SHOPPING