Spondees; NU-6 A Short Interval

This product is the short interval versions of Spondees and NU-6 Form A (Lists 1-4). These short-interval versions give the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way to speed up administration time, but this version is not recommended for young children or the elderly.

The Spondees is a speech threshold (speech reception threshold-SRT) recording. The Spondees, also known as CID W-1, are two-syllable words with equal stress on each syllable, which are employed to obtain thresholds for speech. There are two randomizations of 36 spondaic words spoken without a carrier phrase for adults. The median speech reception threshold (SRT) for normal listeners is 20 dB SPL (0dBHL).

The Northwestern University Auditory Test Number Six (NU-6) Form A is a phonetically balanced word recognition test that employs CNC words. The talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total). The administration time for the NU-6 short interval is 7-14 minutes instead of 10-19 minutes for the NU-6 standard interval.

The Spondees; NU-6 Form A, Short Interval Version  includes a) audio recording and b) printed word lists. This product does not include instructions, normative data, or pictures. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc. Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US locations.

Spondees, NU-6 A, Short Interval Version; Item 145SI; Price $95.00 + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges.

CONTINUE SHOPPING

NU-6 Form C Short Interval

The Northwestern University Auditory Test Number Six (NU-6) Form C (Lists 1-4) Short Interval is a phonetically balanced word recognition test that employs CNC words. The male talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total). This NU-6 Form C product includes all of the same 200 NU-6 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is yet another way to effectively speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-14 minutes instead of 10-19 minutes for the standard interval.

The NU-6 Form C (Lists 1-4) Short Interval includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc.Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

NU-6, Form C Lists 1-4 Short Interval; Item 109SI; Price $59.50 USD + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges

CONTINUE SHOPPING

NU-6 Form B Short Interval

The Northwestern University Auditory Test Number Six (NU-6) Form B (Lists 1-4) Short Interval is a phonetically balanced word recognition test that employs CNC words. The male talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total). This NU-6 Form B product includes all of the same 200 NU-6 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-14 minutes instead of 10-19 minutes for the standard interval.

The NU-6 Form B (Lists 1-4) Short Interval includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc.Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

NU-6, Form B Lists 1-4 Short Interval; Item 108SI; Price $59.50 USD + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges

CONTINUE SHOPPING

NU-6, Form A, Short Interval

The Northwestern University Auditory Test Number Six (NU-6) Form A (Lists 1-4) Short Interval is a phonetically balanced word recognition test that employs CNC words. The male talker has a General American dialect. The articulation function is approximately 4% /dB. There are four lists of 50 words each (200 words total).

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-14 minutes instead of 10-19 minutes for the standard interval.

The NU-6 Form A (Lists 1-4) Short Interval includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc.Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

NU-6, Form A Lists 1-4 Short Interval; Item 107SI; Price $59.50 USD + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges

CONTINUE SHOPPING

W-22 Form A Short Interval

The W-22 Form A Short Interval Version is a phonetically balanced test for word recognition (i.e. speech discrimination). They are made up of consonant-nucleus (CN), nucleus-consonant (NC) and consonant-nucleus-consonant (CNC) words. The talker has a General American dialect. The articulation function is approximately 4% /dB.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-13 minutes instead of 10-18 minutes for the standard interval.

The W-22 Form A Short Interval Version includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc.Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

W-22, Form A Short Interval Version Lists 1-4; Item 103SI; Price $59.50 USD + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges.

CONTINUE SHOPPING

W-22 Form D Short Interval

The W-22 Form D Short Interval Version is a phonetically balanced test for word recognition (i.e. speech discrimination). They are made up of consonant-nucleus (CN), nucleus-consonant (NC) and consonant-nucleus-consonant (CNC) words. The talker has a General American dialect. The articulation function is approximately 4% /dB. This W-22 Form D product includes all of the same 200 W-22 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-13 minutes instead of 10-18 minutes for the standard interval.

The W-22 Form D Short Interval Version includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc.Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

W-22, Form D Short Interval Version Lists 1-4; Item 106SI; Price $59.50 USD + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges.

CONTINUE SHOPPING

W-22 Form B Short Interval

The W-22 Form B Short Interval Version is a phonetically balanced test for word recognition (i.e. speech discrimination). They are made up of consonant-nucleus (CN), nucleus-consonant (NC) and consonant-nucleus-consonant (CNC) words. The talker has a General American dialect. The articulation function is approximately 4% /dB. This W-22 Form B product includes all of the same 200 W-22 words as Form A, but they are presented in a different sequence to prevent memorization.

This short-interval version of the test gives the patient 2.5 seconds to respond instead of the standard four seconds. It is an effective way speed up administration time, but this version is not recommended for young children or the elderly. The administration time for the short interval is 7-13 minutes instead of 10-18 minutes for the standard interval.

The W-22 Form B Short Interval Version includes a) audio recording and b) printed word list. This product does not include instructions or normative data. It is assumed that purchasers of Auditec’s auditory tests are well trained in the use, purpose, and interpretation of basic tests. Available from Auditec, Inc.Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

W-22, Form B Short Interval Version Lists 1-4; Item 104SI; Price $59.50 USD + S&H*
Buy Now Button

NOTE: Online ordering cannot be used for custom CDs. If you want this recording combined on a CD with other recordings, please email auditecinfo@auditec.com with your test selections along with your state or country instead of using the “Buy Now” button. You will receive a Paypal invoice for your custom order.

*INTERNATIONAL CUSTOMERS: Online ordering does not include shipping and handling charges. Please email auditecinfo@auditec.com with your test selections along with your state or country for an exact quote. If you use online ordering, you will be invoiced later for the shipping charges.

CONTINUE SHOPPING