Time Compressed Sentence Test©

The Time Compressed Sentence Test© (TCST) is for identifying and quantifying disorders of auditory processing in children specifically the child’s ability to understand acoustically distorted or rapid rates of speech.  In addition, results of testing with the TCST may yield insights into children with slow reaction times and speed of mental processing. It is considered a monaural low redundancy speech test (monaural separation closure -MSC) sensitive to brainstem and cortical lesions. The developer states the TCST can be administered and scored in less than 15 minutes.

The Time Compressed Sentence Test© includes a) audio recording, and b) manual and score forms as printable pdf files. The extensive manual includes administration, scoring, and interpretation information. Age-specific normative data for ages 6, 7, 8, 9, and 10-11  is included. The developer recommends using the normative data for the 10-11 age category as a guideline for testing patients older than 11. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

Time Compressed Sentence Test© (CD Format); Item 209; Price $129.75 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings and materials are protected by copyright. ©Copyright Time Compressed Sentence Test by NCS Pearson. All Rights Reserved. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright and format to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

⇒Auditec sells a Spanish version of this test.

CONTINUE SHOPPING

Pediatric Speech Intelligibility©

The Pediatric Speech Intelligibility Test© is a test for children ages 3 to 6. It fits in two important auditory processing domains. It can be categorized as both a dichotic test and a monaural low-redundancy speech test (monaural separation closure-MSC) sensitive to low brainstem.

The importance of speech audiometry, especially where the test materials include both monosyllabic words and sentences, has been well established for adults. Experience with performance vs. intensity (PI) functions and message to competition ratio (MCR) functions with adults led to the development of an analogous test for children; the Pediatric Speech Intelligibility (PSI) test.

The PSI includes both monosyllabic words and and two sets of sentences recorded in quiet and with competition (auditory figure ground). The test employs color plates with pictures of animals (animals were used to avoid ethnic biases) which represent either the sentences or the words. It is an extremely useful tool for the investigation of peripheral and auditory processing with children down to a language age of three or slightly younger.

The test includes: a) corresponding laminated color plates, b) audio test recording, and c) manual and score forms as printable pdf files. This extensive manual includes background, administration, and interpretation information including normative data for young children. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US.

Pediatric Speech Intelligibility© (CD Format); Item 183; Price $299.00 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

NU-6 Low Pass Filter 750 Hz©

The NU-6 Low Pass Filter at 750 Hz© is an auditory processing disorder test for adults. It is considered a monaural low-redundancy speech test (monaural separation closure-MSC) sensitive to brainstem and cortical lesions.

The NU-6 Low Pass Filter at 750 Hz© includes a) audio recording, and b) instructions and word list. The NU-6 at 750 Hz includes data for adults only. It would be reasonable to expect children over the age of eleven to test as well (or nearly as well) as adults. Available from Auditec,Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. Free shipping is available to locations within the contiguous US.

NU-6 Low Pass Filter at 750 Hz© (CD Format); Item 169-7; Price $65.00 USD+S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

⇒Auditec sells a similar test called the NU-6 Low Pass Filter at 1000 Hz for children.

CONTINUE SHOPPING

Synthetic Sentence Identification-Contralateral Competing Message©

The Synthetic Sentence Identification© (SSI) can be used to: a) test speech intelligibility, b) test central auditory function, and c) evaluate hearing aid performance. It is considered appropriate for ages 11 and up. The primary signal consists of ten synthetic sentences. The competition is a male talker reading a passage about Davy Crockett. This contralateral competition version has sentences on the left track (channel) and competition on the right. It is a dichotic test using binaural integration sensitive to cortical vs. brain stem lesions.

The Synthetic Sentence Identification© includes: a) audio test recording, b) instructions and score forms as printable pdf files. Normative data is included for hearing aid evaluation only. No normative data is included for the central auditory function; however, the audiologist can uncover useful insight by comparing the patient’s performance on the contralateral and ipsilateral presentations. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

Synthetic Sentence Identification- Contralateral Competing Message© (CD Format); Item 123; Price $104.75 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings and materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

⇒Auditec also sells a Spanish Synthetic Sentence Identification – Contralateral Competing Message.

CONTINUE SHOPPING