Time Compressed Sentence Test©

The Time Compressed Sentence Test© (TCST) is for identifying and quantifying disorders of auditory processing in children specifically the child’s ability to understand acoustically distorted or rapid rates of speech.  In addition, results of testing with the TCST may yield insights into children with slow reaction times and speed of mental processing. It is considered a monaural low redundancy speech test (monaural separation closure -MSC) sensitive to brainstem and cortical lesions. The developer states the TCST can be administered and scored in less than 15 minutes.

The Time Compressed Sentence Test© includes a) audio recording, and b) manual and score forms as printable pdf files. The extensive manual includes administration, scoring, and interpretation information. Age-specific normative data for ages 6, 7, 8, 9, and 10-11  is included. The developer recommends using the normative data for the 10-11 age category as a guideline for testing patients older than 11. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

Time Compressed Sentence Test© (CD Format); Item 209; Price $129.75 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings and materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

⇒Auditec sells a Spanish version of this test.

CONTINUE SHOPPING

Masking Level Difference-Speech©

The Masking Level Difference-Speech© is an auditory processing disorder test. It is considered a binaural interaction test sensitive to low brainstem. This recording employs spondee words imbedded in speech spectrum noise bursts.  It is in two sections; section 1 is where both the noise and the spondees are in phase, section 2 is where the noise is in phase and the spondees are 180 degrees out of phase. A release from masking is expected in the latter section.

The Masking Level Difference-Speech© includes a) audio recording, and b) instructions and score form as printable pdf files. The one-page instructions contain administration, scoring, and interpretation information. Normative data is included, but it is not age-specific. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

Masking Level Difference Speech© (CD Format); Item 204; Price $123.25 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

NU-6 Time Compressed, 30% & 60%©

The NU-6 Time Compressed Words, 30% & 60%© is an auditory processing disorder test in the category of monaural low redundancy. That is, the speech stimuli have been accelerated, but without a shift in pitch. For this product, the all four lists of NU-6 Form A words have been compressed at 30% and 60%. Administration time is 16-33 minutes.

The NU-6 Time Compressed Words, 30% & 60%© includes a) audio recording, and b) word list. This product does not include instructions. The normative data provided with the NU-6 Time Compressed was based on the W-22 Time Compressed. It is for ages 11 and up. It is assumed that purchasers of Auditec’s products are well trained in their use, purpose, and interpretation. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US locations.

NU-6 Time Compressed Words, 30% & 60%© (CD Format); Item 129; Price $82.25 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

⇒If age-specific normative data is needed for young children, consider purchasing the Time Compressed Sentence Test instead.

CONTINUE SHOPPING

Pediatric Speech Intelligibility©

The Pediatric Speech Intelligibility Test© is a test for children ages 3 to 6. It fits in two important auditory processing domains. It can be categorized as both a dichotic test and a monaural low-redundancy speech test (monaural separation closure-MSC) sensitive to low brainstem.

The importance of speech audiometry, especially where the test materials include both monosyllabic words and sentences, has been well established for adults. Experience with performance vs. intensity (PI) functions and message to competition ratio (MCR) functions with adults led to the development of an analogous test for children; the Pediatric Speech Intelligibility (PSI) test.

The PSI includes both monosyllabic words and and two sets of sentences recorded in quiet and with competition (auditory figure ground). The test employs color plates with pictures of animals (animals were use to avoid ethnic biases) which represent either the sentences or the words. It is an extremely useful tool for the investigation of peripheral and auditory processing with children down to a language age of three or slightly younger.

The test includes: a) corresponding laminated color plates, b) audio test recording, and c) manual and score forms as printable pdf files. This extensive manual includes background, administration, and interpretation information including normative data for young children. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US.

Pediatric Speech Intelligibility© (CD Format); Item 183; Price $299.00 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

Rapid Alternating Speech©

The Rapid Alternating Speech© is an auditory processing disorder test for both children and adults using verbal stimuli. This binaural interaction test is sensitive to the low brainstem. It consists of a series of sentences that alternate between the ears as they are spoken. The period is 600 msec. with a 50% duty cycle (i.e. 300 msec. per ear).

Rapid Alternating Speech© includes a) audio recording, and b) instructions and sentence list. The one-page instructions includes information on administration, scoring, and interpretation. Normative data is included, but it is not age specific. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US.

Rapid Alternating Speech© (CD Format); Item 178; Price $65.00 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

Random Gap Detection Test© – Standard & Expanded

The Random Gap Detection Test© -Standard and Expanded version is an auditory processing disorder test for ages 5 and up using non-verbal stimuli. It is considered a temporal test using temporal resolution and is sensitive to cortical particularly left temporal lobe lesions.

The Random Gap Detection Test© (RGDT)-Standard and Expanded includes the standard RGDT in its entirety along with an expanded portion at the end. The expanded portion of the test is included for individuals whose gap detection threshold exceeds 40 msec.  This test begins at time intervals longer than those measured by the standard portion of the RGDT, and includes time intervals of 10 msec. between 40 and 100 msec, and 50 msec. intervals between 100 and 300 msec.  The expanded portion of the test is administered in the same manner as the standard portion.

Individuals who require the expanded portion of the test have already demonstrated abnormal temporal processing abilities. The single purpose is to determine the time interval in which their gap detection thresholds exist. This information can be used to measure improvement in temporal processing abilities following remediation. By definition, patients with temporal processing disorders will have a wide range of gap detection thresholds. Therefore, there are no normative data associated with the expanded portion of the RGDT.

The Random Gap Detection Test©-Standard and Expanded includes a) audio recording, and b) manual and score forms as printable pdf files. The 31-page manual pertains to the standard portion of the test. It is comprised of sections on development, background, administration, and interpretation. It includes normative data for ages 5 and up. An additional sheet with sections on administration and interpretation is included for the expanded portion of the test. Available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to the contiguous US.

Random Gap Detection Test© Standard & Expanded Version (CD Format); Item 208; Price $137.25 USD + S&H*
Buy Now Button

©Copyright 2000 NCS Pearson, Inc. All Rights Reserved. Reproduced by permission.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

Random Gap Detection Test© (RGDT) – Standard

The Random Gap Detection Test© (RGDT)-Standard is an auditory processing disorder test for ages 5 and up using non-verbal stimuli. It is considered a temporal test using temporal resolution and is sensitive to cortical particularly left temporal lobe lesions.

This test is a variation on the AFT-R.  It differs from the AFT-R:  First, in the AFT-R, the stimulus presentations are in serial order from no gap to large gap and back to no gap, often resulting in perseveration in some subjects.  Since randomization successfully eliminates the problem of perseveration, the RGDT gap duration presentations of the stimuli are randomized.  Second, the number of test frequencies has been reduced to four.  Third, Click stimuli have been added. The developer states it takes approximately 10 minutes to administer and score the RGDT.

The Random Gap Detection Test© (RGDT) -Standard includes a) audio recording, and b) manual and score forms as printable pdf files. The 31-page manual is comprised of sections on development, background, administration, and interpretation. It includes normative data for ages 5-7, 8, 9, and 10-11. The developer recommends using the normative data for the 10-11 age category as a guideline for testing patients older than 11. (Normative values for the AFT-R are included for ages 5-70 due to their similarity.) Available from Auditec, Inc.  Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping to contiguous US locations.

Random Gap Detection Test©-Standard (CD Format); Item 207; Price $113.00 USD + S&H*
Buy Now Button

*Administrators who are interested in measuring improvement in temporal processing abilities following remediation should purchase the RGDT-Standard & Expanded version instead.

©Copyright 2000 NCS Pearson, Inc. All Rights Reserved. Reproduced by permission.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

CONTINUE SHOPPING

NCAP Battery©

The NCAP Battery© includes several popular tests for auditory processing disorders at a VERY SPECIAL PRICE!

It includes:

All tests may not be appropriate for all patients. Click on each individual test link to learn more information about the test. This product is available from Auditec, Inc. Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE SHIPPING WITHIN THE CONTIGUOUS US.

NCAP Battery© (CD Format); Item CD117-9; Price $329.75 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

⇒Did you know Auditec makes custom test batteries? Email a list of your test selections to auditecinfo@auditec.com for an exact quote.

⇒Did you know Auditec sells a therapy designed for persons with specific ear deficits on dichotic listening tests called the Constraint-Induced Auditory Therapy (CIAT)?

CONTINUE SHOPPING

Duration Pattern Sequence-Standard©

The Duration Pattern Sequence (DPS) -Standard© is an auditory processing disorder test for ages 11 and up using non-verbal stimuli. It is considered a temporal test using auditory pattern temporal ordering (APTO) and is sensitive to cortical lesions, interhemispheric transfer.

Similar to the Pitch Pattern Sequence (PPS) test, the Duration Pattern Sequence (DPS)-Standard© also explores pattern perception. However, instead of employing tones of different frequencies, the DPS test uses a single frequency tone at two dissimilar durations. Specifically, each pattern is made up of three 1000 Hz tones of one of two durations. That is, two short, one long or one long, two short, in disparate patterns. There is a total of 60 presentations plus 10 additional patterns for practice.

Duration Pattern Sequence-Standard© includes a) audio recording, and b) instructions and score forms as printable pdf files. The one-page instructions consist of administration and interpretation. Normative data is included for adults only. It would be reasonable to expect children over the age of eleven to test as well (or nearly as well) as adults. Available from Auditec, Inc.  Use the “Buy Now” button below or call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. all 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

Duration Pattern Sequence-Standard© (CD Format); Item 198; Price $94.75 USD + S&H*
Buy Now Button

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

*INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

This test also appears on the NCAP Battery (CD117-9).

CONTINUE SHOPPING

APD Battery©

The APD Battery© includes several popular tests for auditory processing disorders at a VERY SPECIAL PRICE!

It includes:

All tests may not be appropriate for all patients. Click on each individual test link to learn more information about the test.

The APD Battery© is available from Auditec, Inc. It includes a) audio recording, and b) instructions and score forms as printable pdf files. ©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. One backup is permitted. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.  Call 1-800-669-9065 (from US) or 314-416-1050 (outside the US) to order. FREE shipping within the contiguous US.

APD Battery© (CD Format); Item CD170-9; Price $329.75 USD + S&H
Buy Now Button

APD Battery© (USB Format); Item USB170-9; Price $335.75 USD + S&H
Buy Now Button

⇒Did you know Auditec makes custom test batteries? Email a list of your test selections to auditecinfo@auditec.com for an exact quote.

⇒Did you know Auditec sells a therapy designed for persons with specific ear deficits on dichotic listening tests called the Constraint-Induced Auditory Therapy© (CIAT)?

CONTINUE SHOPPING