Non-Verbal/Non-Linguistic Category

The following items use tones or sounds to test instead of language. Click on the test name to learn more about the product.

Didn’t find what you were looking for? Check this related category: AUDITORY PROCESSING DISORDER (APD).

⇒Need help figuring out what recording is right for your patients? We are happy to help! Email your questions to auditecinfo@auditec.com.

CONTINUE SHOPPING

Frequency Pattern©

The Frequency Pattern© is an auditory processing disorder test for ages 8 and up using non-verbal stimuli. It is considered a temporal test using auditory pattern temporal ordering (APTO) and is sensitive to cortical lesions, interhemispheric transfer. It was recorded by Dr. Frank Musiek.  Three tone bursts at either of two frequencies are presented monaurally. Administration time is approximately 10 minutes.

The Frequency Pattern© includes a) audio recording, and b) instructions and score form as printable pdf files. The two-page instructions include administration, scoring, and interpretation information. Normative data for ages 8 and up is included. ©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Frequency Pattern© (CD Format); Item 138FM; Price $107.25 USD + S&H Buy Now Button

Frequency Pattern© (USB Format); Item USB138FM; Price $113.25 USD + S&H Buy Now Button

This test also appears on the following product:

CONTINUE SHOPPING

Random Gap Detection Test© (RGDT) – Standard

The Random Gap Detection Test© (RGDT)-Standard is an auditory processing disorder test for ages 5 and up using non-verbal stimuli. It is considered a temporal test using temporal resolution and is sensitive to cortical particularly left temporal lobe lesions.

This test is a variation on the AFT-R.  It differs from the AFT-R:  First, in the AFT-R, the stimulus presentations are in serial order from no gap to large gap and back to no gap, often resulting in perseveration in some subjects.  Since randomization successfully eliminates the problem of perseveration, the RGDT gap duration presentations of the stimuli are randomized.  Second, the number of test frequencies has been reduced to four.  Third, Click stimuli have been added. The developer states it takes approximately 10 minutes to administer and score the RGDT.

The Random Gap Detection Test© (RGDT) -Standard includes a) audio recording, and b) manual and score forms as printable pdf files. The 31-page manual is comprised of sections on development, background, administration, and interpretation. It includes normative data for ages 5-7, 8, 9, and 10-11. The developer recommends using the normative data for the 10-11 age category as a guideline for testing patients older than 11. (Normative values for the AFT-R are included for ages 5-70 due to their similarity.)

©COPYRIGHT Random Gap Detection Test by NCS Pearson. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc.Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Random Gap Detection Test©-Standard (CD Format); Item 207; Price $113.00 USD + S&H* Buy Now Button

Random Gap Detection Test©-Standard (USB Format); Item USB207; Price $119.00 USD + S&H*Buy Now Button

*Administrators who are interested in measuring improvement in temporal processing abilities following remediation should purchase the RGDT-Standard & Expanded version instead.

©Copyright 2000 NCS Pearson, Inc. All Rights Reserved. Reproduced by permission.

CONTINUE SHOPPING

Duration Pattern Sequence-Standard©

The Duration Pattern Sequence (DPS) -Standard© is an auditory processing disorder test for ages 11 and up using non-verbal stimuli. It is considered a temporal test using auditory pattern temporal ordering (APTO) and is sensitive to cortical lesions, interhemispheric transfer.

Similar to the Pitch Pattern Sequence (PPS) test, the Duration Pattern Sequence (DPS)-Standard© also explores pattern perception. However, instead of employing tones of different frequencies, the DPS test uses a single frequency tone at two dissimilar durations. Specifically, each pattern is made up of three 1000 Hz tones of one of two durations. That is, two short, one long or one long, two short, in disparate patterns. There is a total of 60 presentations plus 10 additional patterns for practice.

Duration Pattern Sequence-Standard© includes a) audio recording, and b) instructions and score forms as printable pdf files. The one-page instructions consist of administration and interpretation. Normative data is included for adults only. It would be reasonable to expect children over the age of eleven to test as well (or nearly as well) as adults. ©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Duration Pattern Sequence-Standard© (CD Format); Item 198; Price $94.75 USD + S&H
Buy Now Button

Duration Pattern Sequence-Standard© (USB Format); Item USB198; Price $100.75 USD + S&H
Buy Now Button

This test also appears on the NCAP Battery (CD117-9).

CONTINUE SHOPPING