Auditory Processing Disorder (APD)/Central Auditory Processing (CAP) Category

The following items are considered auditory processing disorder (APD) or central auditory processing (CAP) tests. Click on the test name to learn more about the product.

⇒Need help figuring out what recording is right for your patients? We are happy to help! Email your questions to auditecinfo@auditec.com.

CONTINUE SHOPPING

Dichotic Digits – Standard©

The Dichotic Digits-Standard© test is an auditory processing disorder test using verbal stimuli. It is considered a dichotic test for binaural integration sensitive to brainstem, cortical, and corpus callosal lesions.

This established test assesses the ability to process different materials arriving at the ears simultaneously. Fifty sets of digits, one through nine (except seven, having two syllables) are presented either in single pairs or double pairs. The digits begin and end simultaneously. Administration time is approximately ten minutes.

Dichotic Digits-Standard© includes a) audio recording, and b) instructions and score forms as printable pdf files. The one-page instructions consist of administration, scoring, and interpretation information. Normative data¹ for double digits is included; however, it is only available for ages 11 and up.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Dichotic Digits-Standard© (CD Format); Item 197; Price $94.75 USD + S&H     Buy Now Button

Dichotic Digits-Standard© (USB Format); Item USB197; Price $100.75 USD + S&H   Buy Now Button

¹If age-specific normative data for ages 7 and up is needed, consider purchasing the Dichotic Digits-Musiek version instead.

⇒Did you know Auditec sells a therapy designed for persons with specific ear deficits on dichotic listening tests called the Constraint-Induced Auditory Therapy (CIAT)?

CONTINUE SHOPPING

Frequency Pattern©

The Frequency Pattern© is an auditory processing disorder test for ages 8 and up using non-verbal stimuli. It is considered a temporal test using auditory pattern temporal ordering (APTO) and is sensitive to cortical lesions, interhemispheric transfer. It was recorded by Dr. Frank Musiek.  Three tone bursts at either of two frequencies are presented monaurally. Administration time is approximately 10 minutes.

The Frequency Pattern© includes a) audio recording, and b) instructions and score form as printable pdf files. The two-page instructions include administration, scoring, and interpretation information. Normative data for ages 8 and up is included. ©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Frequency Pattern© (CD Format); Item 138FM; Price $107.25 USD + S&H Buy Now Button

Frequency Pattern© (USB Format); Item USB138FM; Price $113.25 USD + S&H Buy Now Button

This test also appears on the following product:

CONTINUE SHOPPING

Dichotic Digits-Musiek©

The Dichotic Digits test is an auditory processing disorder test for ages 7 and up using verbal stimuli. It is considered a dichotic test for binaural integration sensitive to brainstem, cortical, and corpus callosal lesions.

Dichotic Digits – Musiek© is a test by Dr. Frank Musiek. This version is similar to the Dichotic Digits standard version.  That is, digits from one to ten are presented dichotically.  One set is single pair; the second is double pair.  Usually, the single pair set is for practice. Dichotic Digits-Musiek version includes the digit “seven.” In contrast, the standard version does not include the digit “seven” since it is a two syllable word in contrast to the other nine digits. The Musiek version includes age-specific normative data on double digits for ages 7 and up. The standard version includes normative data on double digits for ages 11 and up.

Is the Musiek version or standard version better? Neither version is considered better. Both versions are popular and widely used. Decisions are mainly based on which version the audiologist was originally trained in or by personal preference. Due to the similarities between the standard and Musiek versions, it is usually unnecessary to purchase both versions.

Dichotic Digits-Musiek© includes a) audio recording, and b) instructions and score form as printable pdf files.  The two-page instructions consist of administration, scoring, and interpretation information. It includes age-specific normative data on double digits for ages 7 and up.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Musiek Dichotic Digits© (CD Format); Item 197FM; Price $102.50 USD + S&H
Buy Now Button

Musiek Dichotic Digits© (USB Format); Item USB197FM; Price $108.50 USD + S&H 
Buy Now Button

This test is also available on the following product:

  • Musiek Dichotic Digits, Musiek Pitch/Frequency Pattern, and Musiek Duration Pattern Sequence combined on one CD; Item 216FM; Price $255.00 USD + S&H

⇒Did you know Auditec sells a therapy designed for persons with specific ear deficits on dichotic listening tests called the Constraint-Induced Auditory Therapy (CIAT)?

CONTINUE SHOPPING

Masking Level Difference-Speech©

The Masking Level Difference-Speech© is an auditory processing disorder test. It is considered a binaural interaction test sensitive to low brainstem. This recording employs spondee words imbedded in speech spectrum noise bursts.  It is in two sections; section 1 is where both the noise and the spondees are in phase, section 2 is where the noise is in phase and the spondees are 180 degrees out of phase. A release from masking is expected in the latter section.

The Masking Level Difference-Speech© includes a) audio recording, and b) instructions and score form as printable pdf files. The one-page instructions contain administration, scoring, and interpretation information. Normative data is included, but it is not age-specific.

©COPYRIGHT NOTICE: Auditec’s recordings are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited. Email questions regarding copyright to auditecinfo@auditec.com.

Available from Auditec, Inc. Use the “Buy Now” button below to order. FREE shipping within the contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Masking Level Difference Speech© (CD Format); Item 204; Price $123.25 USD + S&H 
Buy Now Button

Masking Level Difference Speech© (USB Format); Item USB204; Price $129.25 USD + S&H 
Buy Now Button

CONTINUE SHOPPING

NU-6 Time Compressed, 30% & 60%©

The NU-6 Time Compressed Words, 30% & 60%© is an auditory processing disorder test in the category of monaural low redundancy. That is, the speech stimuli have been accelerated, but without a shift in pitch. For this product, the all four lists of NU-6 Form A words have been compressed at 30% and 60%. Administration time is 16-33 minutes.

The NU-6 Time Compressed Words, 30% & 60%© includes a) audio recording, and b) word list. This product does not include instructions. The normative data provided with the NU-6 Time Compressed was based on the W-22 Time Compressed. It is for ages 11 and up. It is assumed that purchasers of Auditec’s products are well trained in their use, purpose, and interpretation.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc. Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

NU-6 Time Compressed Words, 30% & 60%© (CD Format); Item 129; Price $82.25 USD + S&H Buy Now Button

NU-6 Time Compressed Words, 30% & 60%© (USB Format); Item USB129; Price $88.25 USD + S&H Buy Now Button

⇒If age-specific normative data is needed for young children, consider purchasing the Time Compressed Sentence Test instead.

CONTINUE SHOPPING

Pediatric Speech Intelligibility©

The Pediatric Speech Intelligibility Test© is a test for children ages 3 to 6. It fits in two important auditory processing domains. It can be categorized as both a dichotic test and a monaural low-redundancy speech test (monaural separation closure-MSC) sensitive to low brainstem.

The importance of speech audiometry, especially where the test materials include both monosyllabic words and sentences, has been well established for adults. Experience with performance vs. intensity (PI) functions and message to competition ratio (MCR) functions with adults led to the development of an analogous test for children; the Pediatric Speech Intelligibility (PSI) test.

The PSI includes both monosyllabic words and and two sets of sentences recorded in quiet and with competition (auditory figure ground). The test employs color plates with pictures of animals (animals were used to avoid ethnic biases) which represent either the sentences or the words. It is an extremely useful tool for the investigation of peripheral and auditory processing with children down to a language age of three or slightly younger.

The test includes: a) corresponding laminated color plates, b) audio test recording, and c) manual and score forms as printable pdf files. This extensive manual includes background, administration, and interpretation information including normative data for young children.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc. Use the “Buy Now” button below to order. FREE shipping to contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Pediatric Speech Intelligibility© (CD Format); Item 183; Price $299.00 USD + S&H
Buy Now Button

Pediatric Speech Intelligibility© (USB Format); Item USB183; Price $305.00 USD + S&H
Buy Now Button

CONTINUE SHOPPING

Rapid Alternating Speech©

The Rapid Alternating Speech© is an auditory processing disorder test for both children and adults using verbal stimuli. This binaural interaction test is sensitive to the low brainstem. It consists of a series of sentences that alternate between the ears as they are spoken. The period is 600 msec. with a 50% duty cycle (i.e. 300 msec. per ear).

Rapid Alternating Speech© includes a) audio recording, and b) instructions and sentence list. The one-page instructions includes information on administration, scoring, and interpretation. Normative data is included, but it is not age specific.

©COPYRIGHT NOTICE: Auditec’s materials are protected by copyright. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc. Use the “Buy Now” button below to order. FREE shipping to contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Rapid Alternating Speech© (CD Format); Item 178; Price $65.00 USD + S&H
Buy Now Button

Rapid Alternating Speech© (USB Format); Item USB178; Price $71.00 USD + S&H
Buy Now Button

CONTINUE SHOPPING

Random Gap Detection Test© – Standard & Expanded

The Random Gap Detection Test© -Standard and Expanded version is an auditory processing disorder test for ages 5 and up using non-verbal stimuli. It is considered a temporal test using temporal resolution and is sensitive to cortical particularly left temporal lobe lesions.

The Random Gap Detection Test© (RGDT)-Standard and Expanded includes the standard RGDT in its entirety along with an expanded portion at the end. The expanded portion of the test is included for individuals whose gap detection threshold exceeds 40 msec.  This test begins at time intervals longer than those measured by the standard portion of the RGDT, and includes time intervals of 10 msec. between 40 and 100 msec, and 50 msec. intervals between 100 and 300 msec.  The expanded portion of the test is administered in the same manner as the standard portion.

Individuals who require the expanded portion of the test have already demonstrated abnormal temporal processing abilities. The single purpose is to determine the time interval in which their gap detection thresholds exist. This information can be used to measure improvement in temporal processing abilities following remediation. By definition, patients with temporal processing disorders will have a wide range of gap detection thresholds. Therefore, there are no normative data associated with the expanded portion of the RGDT.

The Random Gap Detection Test©-Standard and Expanded includes a) audio recording, and b) manual and score forms as printable pdf files. The 31-page manual pertains to the standard portion of the test. It is comprised of sections on development, background, administration, and interpretation. It includes normative data for ages 5 and up. An additional sheet with sections on administration and interpretation is included for the expanded portion of the test.

©COPYRIGHT Random Gap Detection Test by NCS Pearson. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc. Use the “Buy Now” button below to order. FREE shipping to the contiguous US. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Random Gap Detection Test© Standard & Expanded Version (CD Format); Item 208; Price $137.25 USD + S&H
Buy Now Button

Random Gap Detection Test© Standard & Expanded Version (USB Format); Item USB208; Price $143.25 USD + S&H
Buy Now Button

CONTINUE SHOPPING

Random Gap Detection Test© (RGDT) – Standard

The Random Gap Detection Test© (RGDT)-Standard is an auditory processing disorder test for ages 5 and up using non-verbal stimuli. It is considered a temporal test using temporal resolution and is sensitive to cortical particularly left temporal lobe lesions.

This test is a variation on the AFT-R.  It differs from the AFT-R:  First, in the AFT-R, the stimulus presentations are in serial order from no gap to large gap and back to no gap, often resulting in perseveration in some subjects.  Since randomization successfully eliminates the problem of perseveration, the RGDT gap duration presentations of the stimuli are randomized.  Second, the number of test frequencies has been reduced to four.  Third, Click stimuli have been added. The developer states it takes approximately 10 minutes to administer and score the RGDT.

The Random Gap Detection Test© (RGDT) -Standard includes a) audio recording, and b) manual and score forms as printable pdf files. The 31-page manual is comprised of sections on development, background, administration, and interpretation. It includes normative data for ages 5-7, 8, 9, and 10-11. The developer recommends using the normative data for the 10-11 age category as a guideline for testing patients older than 11. (Normative values for the AFT-R are included for ages 5-70 due to their similarity.)

©COPYRIGHT Random Gap Detection Test by NCS Pearson. Each product represents one license for up to two audiometers at one location. Sharing, uploading to servers, publishing to the internet, and all other forms of distribution are prohibited.

Available from Auditec, Inc.Use the “Buy Now” button below to order. FREE shipping to contiguous US locations. INTERNATIONAL CUSTOMERS: Importers are responsible for duties and taxes. Auditec advises your organization to contact your government to estimate tax prior to ordering.

Random Gap Detection Test©-Standard (CD Format); Item 207; Price $113.00 USD + S&H* Buy Now Button

Random Gap Detection Test©-Standard (USB Format); Item USB207; Price $119.00 USD + S&H*Buy Now Button

*Administrators who are interested in measuring improvement in temporal processing abilities following remediation should purchase the RGDT-Standard & Expanded version instead.

©Copyright 2000 NCS Pearson, Inc. All Rights Reserved. Reproduced by permission.

CONTINUE SHOPPING